DT System Technical Guide 10
+
+
-
-
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Remove the Jumper
set to Normally Open on the
Unlock Relay mode.(default)
1
2
3
DIPS-5: default set to off,
unlocking time is 1 second.
(In most cases, 1 second is
work for Power-to-Unlock type)
1 2 3 4 5 6
ON
DIPS
JP_LK
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Remove the Jumper
set to Normally Closed on the
Unlock Relay mode on DT software.
1
2
3
+
+
-
-
DIPS-5: set to on,
unlocking time is 5 seconds.
1 2 3 4 5 6
ON
DIPS
JP_LK
12V 300mA
Jumper set to 2-3 position
DIPS-5: set to on,
unlocking time is 5 seconds.
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
1
2
3
+
-
1 2 3 4 5 6
ON
DIPS
JP_LK
set to Normally Closed on the
Unlock Relay mode on DT software.
2. Additional power supply
When the electronic lock is over 12 Vdc, additional power supply for the lock is needed.
• The power supply for the lock must be less than 48Vdc 1.5A.
• The Jumper must be removed when using additional power supply. The default is set for PowertoUnlock
type(Normally open), if use PowerofftoUnlock type, change the Unlock Relay mode to Normally closed
on the Parameter tab of DT CONFIG software.
• If different unlocking time is needed to be congured, please use the DT CONFIG software to change the setting
on the Parameter tab(see the program section).
C. Connection for PowertoUnlock type:
B. Connection for PowerofftoUnlock type:
D. Connection for PowerofftoUnlock type:
Note:
Cut off this line when using
additional power supply
Note:
Cut off this line when using
additional power supply